DuraVent 4PVL-HSC Guida di Installazione

Navigare online o scaricare Guida di Installazione per Camini DuraVent 4PVL-HSC. DuraVent 4PVL-HSC Installation Guide Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 16
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
PelletVEnt
for Multi-Fuel
Multi-fuel venting system.
UL 641, UL 1777
Installation Instructions
Vedere la pagina 0
1 2 3 4 5 6 ... 15 16

Sommario

Pagina 1 - PelletVEnt

PelletVEntfor Multi-FuelMulti-fuel venting system.UL 641, UL 1777Installation Instructions

Pagina 2

10Bracket to hold the Tee to the rear of the appliance is mandatory. If it is desired to mount the Tee Support to the rear of the stove, obtain approv

Pagina 3

11Figure 10RIGIDPELLET VENTPELLET VENT CAPTALL CONEFLASHINGSCREW STORMCOLLAR TO OUTERLINER OF PIPE WITHSHEET METALSCREWS. THIS WILLSUPPORT SYSTEM.FLEX

Pagina 4 - INSTALLATION NOTES

12masonry chimney has an oset. If an oset exists, then a section of Flex Pipe will be needed to accommodate the oset.B. A Tee is installed at the b

Pagina 5 - INSTRUCTIONS

13INSTALLATION IN A CATHEDRAL CEILING1. Mark a line on the side of the Cathedral Ceiling Support Box to correspond to the line of the roof pitch, as s

Pagina 6

14bead of non-hardening sealant around the outside top edges of the Support Box so as to make a seal between the box and the roof. Clean out any combu

Pagina 7

15exterior metal parts with high temperature, rustproof paint. This is highly recommended, particularly in areas near the ocean.6. In case of a chimne

Pagina 8

PelletVent® are registered trademarks of M&G DuraVent, Inc.All rights reserved, ©2012 M&G DuraVent is a member of M&G Group. Customer Ser

Pagina 9 - FIREPLACE

A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

Pagina 10 - SIDE OF MASONRY CHIMNEY

3CONTENTSCLEARANCES AND APPLICATIONS . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . .. . . . . . 4VENT LISTING, INSTALLATION NOTES . .

Pagina 11 - Figure 14

4CLEARANCES AND APPLICATIONSDuraVent’s PelletVent and PelletVent for Multi-Fuel is listed by UnderwritersLaboratories as vent for listed oil-, pellet-

Pagina 12

5provided it is inside the replace, and the replace has completely sealed surroundings.11. Do not connect B-Vent pipe with aluminum liners to pellet

Pagina 13 - INSTALLATION IN A CATHEDRAL

6push together and twist to lock.C. Continue to assemble pipe as described in Step 2.4. If the ue exit is on the back of stove, and an exterior verti

Pagina 14 - CLEANING AND MAINTENANCE

7desired (Figure 6):A. Place the appliance according to manufacturer’s instructions.B. Connect the Pipe Adapter to back of stove and attach sucient p

Pagina 15

8B. Visually inspect with a ashlight the condition of the interior of the chimney for cleanliness and structural integrity. All evidence of soot and

Pagina 16 - L502 06/2012

9vertically plumb, then slip the Adjustable Length up and twist lock it to the Chimney Adapter. Once all the components are rmly seated and properly