PelletVEntfor Multi-FuelMulti-fuel venting system.UL 641, UL 1777Installation Instructions
10Bracket to hold the Tee to the rear of the appliance is mandatory. If it is desired to mount the Tee Support to the rear of the stove, obtain approv
11Figure 10RIGIDPELLET VENTPELLET VENT CAPTALL CONEFLASHINGSCREW STORMCOLLAR TO OUTERLINER OF PIPE WITHSHEET METALSCREWS. THIS WILLSUPPORT SYSTEM.FLEX
12masonry chimney has an oset. If an oset exists, then a section of Flex Pipe will be needed to accommodate the oset.B. A Tee is installed at the b
13INSTALLATION IN A CATHEDRAL CEILING1. Mark a line on the side of the Cathedral Ceiling Support Box to correspond to the line of the roof pitch, as s
14bead of non-hardening sealant around the outside top edges of the Support Box so as to make a seal between the box and the roof. Clean out any combu
15exterior metal parts with high temperature, rustproof paint. This is highly recommended, particularly in areas near the ocean.6. In case of a chimne
PelletVent® are registered trademarks of M&G DuraVent, Inc.All rights reserved, ©2012 M&G DuraVent is a member of M&G Group. Customer Ser
A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE
3CONTENTSCLEARANCES AND APPLICATIONS . . . . . . .. . . . . . . . . . . . . . . . .. . . . . . . . .. . . . . . 4VENT LISTING, INSTALLATION NOTES . .
4CLEARANCES AND APPLICATIONSDuraVent’s PelletVent and PelletVent for Multi-Fuel is listed by UnderwritersLaboratories as vent for listed oil-, pellet-
5provided it is inside the replace, and the replace has completely sealed surroundings.11. Do not connect B-Vent pipe with aluminum liners to pellet
6push together and twist to lock.C. Continue to assemble pipe as described in Step 2.4. If the ue exit is on the back of stove, and an exterior verti
7desired (Figure 6):A. Place the appliance according to manufacturer’s instructions.B. Connect the Pipe Adapter to back of stove and attach sucient p
8B. Visually inspect with a ashlight the condition of the interior of the chimney for cleanliness and structural integrity. All evidence of soot and
9vertically plumb, then slip the Adjustable Length up and twist lock it to the Chimney Adapter. Once all the components are rmly seated and properly