Duravent DuraConnect Manuale Utente

Navigare online o scaricare Manuale Utente per Apparecchiature per l'aria compressa Duravent DuraConnect. DuraVent DuraConnect User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 12
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
DuraConnect



Installation Instructions
Vedere la pagina 0
1 2 3 4 5 6 ... 11 12

Sommario

Pagina 1 - DuraConnect

DuraConnectInstallation Instructions

Pagina 2 - WITH THESE INSTRUCTIONS

using a Gas Vent Support installed under the ashing. As an alternative to using the Gas Vent Support, you can use a Wall Strap if there is a roof j

Pagina 3

Figure 7

Pagina 4 - APPLICATIONS

DuraConnect is a registered trademark of the M&G DuraVent, Inc.All rights reserved. Made in the USA. M&G DuraVent is a member of M&G Grou

Pagina 5 - FITTINGS

A MAJOR CAUSE OF VENT RELATED FIRES IS FAILURE TO MAINTAIN REQUIRED CLEARANCES (AIR SPACES) TO COMBUSTIBLE MATERIALS. IT IS OF THE UTMOST IMPORTANCE

Pagina 6 - INSTALLATION PROCEDURE

CONTENTSIntroduction, Applications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4Connector pipe, Clearances, Fitt

Pagina 7 - Figure 4

It is important that vents and vent connectors be installed only in accordance with simpson dura-vent installation instructions. A major cause of re

Pagina 8 - NATIONAL CODES

CONNECTOR PIPEDuraConnect & DuraConnect II exible systems should be installed in as short and straight a run as possible. In accordance with NFP

Pagina 9 - ADDENDUM

of a restop plate at the ceiling.For multiple gas installations, such as a furnace and hot water heater, a wide selection of "Tees" and &q

Pagina 10

Figure 3Figure 5Figure 6Figure 41"ORWALL STRAPFIRESTOPFURNACEB-VENTWATER HEATERCEILING54321"1AORWALL STRAPFIRESTOPFURNACEB-VENTWATER HEATER

Pagina 11 - Figure 7

and an Appliance Connector for DuraConnect. Secure with sheet metal screws.TECHNICAL REPORTUL listing:DuraConnect is the rst and only single wall ve

Pagina 12 - 

SBCCI Compliance Report 9135 ICBO Evaluation Report 4895 BOCA Research Report 90-82 Patent 5,165,732National, Standard, and Uniform Mechanical Codes.

Commenti su questo manuale

Nessun commento